Please choose the options, which are relevant for the product enquiry.
The evaporation humidifier is the exclusive way of humidification of the ECO Appliance Line. The Premium-Line furthermore includes the high-precision controllable ultrasonic atomization.
LED lighting (warm white) by two vertically arranged LED bars on the test room's back panel.
LED lighting for plant growth by two vertically arranged LED bars on the test room's back panel. Individual mixing of the red and blue components of the spectrum is possible by means of the option multichannel light control.
Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.
Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.
Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.
Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.
The multi-channel light control allows control and dimming in groups of LEDs of different lighting levels and light spectra. Program-controlled change of the light spectrum is possible.
The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests. Their maximum carrying capacity is up to 40 kg.
Free view on the specimen is ensured by an optional glazed door.
A 45 mm duct in the side panel allows insertion of measuring lines and hoses into the test room. Delivery including cover.
Gas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes.
2 Fresh air rosettes, air flow rate adjustable, located in the upper and lower area of the test room, ensure the fresh air supply into the test room. Application: Plants, test animals
Mobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake.
Test room socket for connection of shakers, magnetic mixers etc. in the test room. Switching-on times can be freely programmed by means of the CONTROL2015 touch.
Electromagnetic door release by means of the CONTROL2015 touch. Door unlocking only after successful authorization with entry in the logbook (name, date, time).
Export execution for power supply 110 V/60 Hz.
Additional measuring sensor PT1000 for temperature control and recording of specimen.
Analogue output test room temperature for external recorder Signal 0-10 V, 0-20 mA, 4-20 mA
Analogue output test room humidity for external recorder Signal 0-10 V, 0-20 mA, 4-20 mA
- Monitoring of up to 32 appliances - Compatible with Control 2000 and Control2015 touch - Data logging and graph representation - Logging of door openings with time stamp - Logging of alarms with time stamp - Automated daily print is possible - Weekly and monthly print - Archiving per day and control circuit - Automated backup on server drive
- Monitoring of appliances with Control2015 touch - Data safety in conformity with the guidelines 21CFR Part 11 - All events are recorded in a digital logbook, inseparably connected with the recorded data. - Signature in connection with the user management of the appliances - Automated prints - Automated backup on server drive
Calibration on site with 9 spatially distributed sensors with a temperature value.
Calibration on site with 9 spatially distributed sensors with a temperature value.
We are always ready to support the validation of your appliances. If desired, the validation can be executed by our company. The validation includes the necessary measurements, as well as any documents, such as DQ, IQ, OQ and PQ, manuals, wiring diagrams, plans, appliance logbook, manufacturer certificates for the sensors and for the most important components. If required, we are also at your disposal for the annual recalibration.
Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.
Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.