Sie befinden sich hier: Startseite » Ex-proof Equipment » Safety X-Linie

Safety X-Linie

If ignitable mixtures exist temporarily at the installation place, highest safety standards and thus the completely ex-proof appliances of the RUMED® Safety X-Line are required. They are approved for operation in explosive areas of zone 1.

Despite these increased safety requirements, the RUMED® Safety X-Line offers almost the same equipment possibilities as the Safety T-Line.

Units of the X-Line can be installed in zone 1 and zone 2. This is possible due to a multitude of different types of protection (pressure-proof housing, intrinsic safety, increased safety, encapsulation).

All appliances of the X-Line have successfully passed a demanding type examination according to annex III of the ATEX 2014/34/EU allowing an application in zone 1 and zone 2. RUMED® is a manufacturer of explosion-proof equipment being certified according to ISO 80079-34. This involves periodical inspections (audits) by a notified authority and a highly effective quality management system of worldwide importance.

The units are suitable for storage and tests of material of the temperature classes T1, T2 and T3 of explosion group IIA and IIB.

General view of the most important advantages:

  • Entire system Ex Logo II 2 G Ex db eb h [ib] ib mb IIB T3 Gb
  • Approved for installation in the ex area zone 1
  • 5 Test room sizes: 320 l to 1.640 l
  • Test room and external housing of solvent-resistant stainless steel
  • Recirculating air fan for good temperature distribution in space
  • Easy handling by means of a precise temperature controller with digital display
  • Temperature ranges from -20 °C to +80 °C
  • Optional dehumidification and humidification
  • Possibility of calibration and validation
  • Robust and extremely durable

Standard Equipment
Safety X-Line

Switch cabinet – pressure-proof housing

The switch cabinet is equipped with a pressure-proof housing. Thus, large part of the electric system can be manufactured using standard components. This pressure-proof housing „d“ according to DIN EN 60079-1 effectively avoids inflammation of the atmosphere surrounding the switch cabinet.


Digital control

Operation and control of the appliances is effected by means of the modern, digital control unit. A digital interface for this control unit is optionally available. The option Program Control allows complex, several days‘ programs with cyclizations and loops.


Fan motor

Up to a working temperature of 35 °C, the fan and the integrated motor are located in the test room. For higher working temperatures, the motor driving the fan wheel in the test room will be installed outside the appliance. In any case, the motor will be disconnected permanently by a protective motor switch in case of a failure.


Refrigerating machine – open compressor with belt drive

The open refrigerating machine is driven by a conductive V-belt and a motor with pressure-proof housing. The explosion-proof solenoid valve bypass system ensures precise control. The refrigerating system is protected against malfunction by an explosion-proof pressure switch, as well as by a protective motor switch.

TypX 320X 500X 820X 1000X 1640
Entire unit explosion-proof Ex Logo II 2 G Ex db eb h [ib] ib mb IIB T3 Gb
Volume (l)32050082010001640
Minimum temperature0 °C0 °C0 °C0 °C0 °C
Maximum temperature+35 °C+35 °C+35 °C+35 °C+35 °C
Temperature deviation in time ( °C)±0,5 °C±0,5 °C±0,5 °C±0,5 °C±0,5 °C
Height (mm)9901500150015001500
Width (mm)6106106102 x 6102 x 610
Depth (mm)585585935585935
Number of shelves (standard delivery scope)34488
Maximum load per shelf (kg)2525252525
Unit
Height (mm)16002105210521052105
Width (mm)76076076015201520
Depth (mm)90090012509001250
Electric connection (V/Hz)400/230/50400/230/50400/230/50400/230/50400/230/50
Options
Additional shelfX0320-01X0500-01X0820-01X1000-01X1640-01
Additional shelf, reinforced (maximum load per shelf 50 kg)X0320-02X0500-02X0820-02 X1000-02X1640-02
Glazed panel door, no pane heatingX0320-03X0500-03X0820-03X1000-03X1640-03
Extension of temperature range down to -20 °CX0320-04X0500-04X0820-04X1000-04X1640-04
Extension of temperature range up to +80 °C*X0500-05X0820-05X1000-05X1640-05
Speed rate in temperature change 1 °C/min (0 °C to +35 °C)X0320-06X0500-06X0820-06X1000-06X1640-06
Speed rate in temperature change 1 °C/min (-20 °C to +80 °C)X0320-07X0500-07X0820-07X1000-07X1640-07
Humidification by evaporative humidifier + dehumidificationX0320-20X0500-20X0820-20X1000-20X1640-20
*Unit depth is then + 225 mm

EX Options Digital recorder

Digital recorder

The digital recorder of the X-Line is working without any paper, and it can be equipped with a digital interface, just like the con­troller. Due to corresponding transmitters, recording and control can be executed in areas being not explosion-proof.
Order-No.: X9990-01


EX Options Tubular port

Tubular port

A 45 mm duct in the side panel allows insertion of measuring lines and hoses into the test room. Delivery including cover.
Order-No.: X9930-01


EX Options Closing plug

Closing plug

Gas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes.

Order No.: X9930-02


EX Options Steering rollers

Steering rollers

Mobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake.
Order-No.: X9930-04


Technical ventilation

If an evaporation of solvents cannot be avoided by procedural means, a technical ventilation is compulsory. The ventilation prevents the formation of a permanent explosive atmosphere (zone 0). Its efficiency is supervised redundantly by two flow switches. Depending on the density, the gases will be exhausted out of the unit either at ceiling level or at floor level. The air supply is effected vice-versa, at floor level or at ceiling level, to ensure, that the air flow covers all areas of the room. The fan ensures a high ventilation rate.
Order-No.: X9980-01


Humidification

Equipped with the options humidification and dehumidification, an explosion-proof cold-heat test cabinet becomes an explosion-proof climatic test cabinet. Humidification of the Safety T-Line is effected by a specially controlled ultrasonic atomizer. Humidification of the Safety X-Line is realized by an explosion-proof version of evaporation humidification being installed in the test room. A plate heat-exchanger of stainless steel, which is optimized for this application, effects a dehumidification by falling below dewpoint. This combination of humidification and dehumidification allows a wide range of temperature/humidity combinations. The sensor is a temperature-compensated, capacitive sensor, which can be calibrated.