Sie befinden sich hier: Startseite » Stability Test Chambers

Walk-in Chambers – for everything requiring space

The RUMED® Walk-in Environmental Test Chambers provide customized solutions in XXL format for any kind of climatic tests in science and industry.

You are looking for a solution for storage of stability specimen, a measuring room for standard climates, plant Gassing with CO2, or even an explosion-proof chamber for storage of aerosol cans? The RUMED® Walk-in Environmental Test Chambers make almost everything possible. Due to their vari­able size and equipment, the test chambers provide customized solutions for each place of installation and each task.

General view of the most important advantages:

  • Test room volume up to 40 m³
  • Individual dimensions, extremely variable equipment
  • Available as temperature chamber, climatic chamber or plant growth chamber
  • Intuitive handling by means of the Control2015 touch
  • Gapless documentation
  • Energy-saving refrigeration technology
  • Possibility of calibration and validation
  • Optionally available in explosion-proof execution
  • RUMED® Chambers are space-saving, since they can be installed directly side by side.

  • Stability test of drugs according to the ICH Guideline in the climatic chamber.

  • Breeding of high growing plants in the light chamber.


Walk-in Environmental Test Chambers One chamber – many possibilities

The RUMED® Walk-in Chambers have a wide application range:

  • Stability test according to the ICH Guideline
  • Measurement at standard climates
  • Plant growth
  • Storage aerosol cans (Ex-proof version)



The chambers consist of sandwich elements with tongue and groove profile. Thanks to this manufacturing technology, also an installation in confined locations is possible. The insulation layer of the sandwich elements consists of high-quality polyurethane foam. The insulation thickness is between 80 and 120 mm, depending on the chosen temperature range.




The chamber floor consists of non-slip structural stainless steel. The standard surface of the sandwich elements is manufactured from sheet steel with white coating. Optionally, an execution in stainless steel is available.




The standard installation of the chambers is at ground level. If the chamber shall be accessible with a trolley, this can either be realized by means of a ramp or by reduction of the ground level by the customer.




The standard stop of the lockable door is outside, but also a version with inside stop is available. The door can be equipped with a window for observation of the specimen. A porthole of 225 mm diameter or a square glazing of the size 400 x 400 mm are available. Incidence of extraneous light can be avoided by a shutter on the window.




The chamber is equipped with aluminium shelves. Also an execution in stainless steel or a mobile shelving system is available.




An efficient recirculating air fan with bionic fan wheel ensures a perfect temperature and humidity accuracy in space at a low noise level. The humidification is realized by a redundant ultrasonic humidifier. The refrigerating machine is installed space-saving above the switch cabinet



The Control2015 touch takes over the entire control and documentation. All components are easily accessible for maintenance purposes.

Installation of a double climatic chamber at the customer's site.

Installation of a double climatic chamber at the customer’s site.

Functional check within the framework of qualification.

Functional check within the framework of qualification.

Redundant control and air-conditioning technology for highest requirements on the reliability.

Redundant control and air-conditioning technology for highest requirements on the reliability.

Ground level access into the chambers by means of installation in a pit provided by the customer.

Internal ramp, if a ramp in front of the door is not possible due to space constraints or if it is not admissible because of an escape route.

Lockable door with emergency opening and porthole for control to avoid disturbance of the climate by opening of the door.

Ground level access into the chambers by means of installation in a pit provided by the customer.

Lockable door with emergency opening and porthole for control to avoid disturbance of the climate by opening of the door.

Lockable door with emergency opening and porthole for control to avoid disturbance of the climate by opening of the door.

Shelf installation with 2 aisles in customized design.

Shelf installation with 2 aisles in customized design.

Air-conditioning unit at the front wall of the cell, if the height is not sufficient for installation of the air-conditioning unit below the chamber ceiling.

Air-conditioning unit at the front wall of the cell, if the height is not sufficient for installation of the air-conditioning unit below the chamber ceiling.

Detail of the air-conditioning unit at the front wall of the cell, if the height is not sufficient for installation of the air-conditioning unit below the chamber ceiling.

Detail of the air-conditioning unit at the front wall of the cell, if the height is not sufficient for installation of the air-conditioning unit below the chamber ceiling.

Inspection flap in the floor or in the wall for access to covered inspection openings for reasons of maintenance and cleaning.

Inspection flap in the floor or in the wall for access to covered inspection openings for reasons of maintenance and cleaning.

Direct water cooling without refrigerating machine for highest energy efficiency. In this case, an additional air-conditioning system of the customer for removal of the waste heat is not required.

Direct water cooling without refrigerating machine for highest energy efficiency. In this case, an additional air-conditioning system of the customer for removal of the waste heat is not required.

Dehumidification by means of a self-regenerating adsorption drier, if the water flow temperature is not sufficient for dehumidification.

Dehumidification by means of a self-regenerating adsorption drier, if the water flow temperature is not sufficient for dehumidification.