Product Information

  • Temperature 0 °C to +50 °C, optionally -30 °C to +80 °C
  • Test Room 1060 Litres
  • Stainless Steel Execution
  • Program Controller Control2015touch
  • Screen Recorder and USB/Ethernet
  • Optional Humidity and Light
TypeKBS-P1060
Test Room
Volume1060 l
Temperature Range0 °C to +50 °C
Deviation in Time±0,5 °C
Height1500 mm
Width2 x 610 mm
Depth585 mm
Number of shelves 6
Maximum load per shelf25 kg
Appliance
Height2105 mm
Width1460 mm
Depth820 mm
Electr. Connection230 V / 50 Hz
Net weight of the standard unit260 kg
Refrigerant
Type / GWPR290 / 3
CO2-Equivalent< 0,001 t

Enquiry Questionnaire

Please choose the options, which are relevant for the product enquiry.

Temperature Options

test

Extension of the minimum temperature to -20 °C.

test

Extension of the minimum temperature to -30 °C.

test

Extension of the maximum temperature to +80 °C.

test

Augmentation of the speed of temperature change to 2 °C/min in the temperature range of 0 °C to +80 °C.

Humidity Options

For all applications requiring an exact setting of the air humidity, the ultrasonic atomization in combination with the dehumidification methods is the best choice. The ultrasonic dehumidifier is separated from the explosion-proof test room by means of a zone separation valve. The desired humidity can be preselected by means of the electronic PID-controller, which is integrated in the Control2015 touch. Dehumidification is realized by condensation at a special plate heat-exchanger.

The dehumidification is realized by condensation or freezing of the water vapour contained in the air at a plate heat-exchanger of stainless steel in special design. Periodical hot gas defrosting thaws the frozen water, which will be dripping into the condensate drain.

Extension of the minimum humidity range to 10 % relative humidity up to a minimum temperature of +20 °C.

Extension of the minimum humidity range to 10 % relative humidity up to a minimum temperature of +20 °C by means of dried compressed air of the customer.

Ion exchanger for direct connection to the drinking water pipe, if demineralized water supply is not available.

Canister for water supply at installation places without water connection.

Light Options

The vertically arranged LED light bars allow free and flexible arrangement of the test room. Appliances of the Eco-Line are equipped with 2 LED bars on the back panel of the test room, those of the Premium-Line are equipped with 2 LED bars on each side panel.

LED lighting of the test room by two vertically arranged LED bars. Individual mixing of the red and blue components of the spectrum is possible by means of the option multichannel light control.

Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.

Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.

This execution had been developed particularly for in vitro cultivation. It is equipped with a special recirculating air system avoiding condensation. No formation of condensate drops means: no contamination of the cultures by dripping water and no burning glass effect. The appliance is equipped with 4 illuminated levels, which can be switched and dimmed independently of each other by means of the option multi-channel light control.

Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.

Appliances with LED lighting in several levels are the best choice for plants with low growth height. They distinguish by optimum economy of space.

The multi-channel light control allows control and dimming in groups of LEDs of different lighting levels and light spectra. Program-controlled change of the light spectrum is possible.

CO2 Gassing

As 4th module, the CO2 gassing allows examination of the short- and long-term effects of the so-called "CO2 manuring effect" on plants of categories C3 or C4. The CO2 sensor is equipped with a multi-position CO2 and temperature adjustment, which is a guarantee for outstanding measurement accuracy. Due to the NDIR two-beam method, the sensor is insensitive to soiling, and ageing effects are compensated automatically. Furthermore, the CO2 sensor has an excellent long-term stability and auto-calibration.

LED lighting of the test room by two vertically arranged LED bars. Individual mixing of the red and blue components of the spectrum is possible by means of the option multichannel light control.

Optional Accessories

Their maximum carrying capacity is up to 25 kg.

The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests. Their maximum carrying capacity is up to 50 kg.

Their maximum carrying capacity is up to 50 kg. The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests.

The triple glazed glass panel door always ensures an optimum view into the test room. A pane heating avoids formation of condensate.

Another option: the internal glass door. When the appliance door is open, it allows a visual check of the specimen - without any unnecessary disturbance of the climate in the test room.

The stainless-steel plate evaporator is always recommendable, whenever acid resistance is required, such as for Drosophila cultivation.

A 45 mm duct in the lateral panel allows insertion of measuring lines and hoses into the test room. Delivery including cover.

Gas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes.

2 Fresh air rosettes, air flow rate adjustable, located in the upper and lower area of the test room, ensure the fresh air supply into the test room. Application: Plants, test animals

Mobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake.

Test room socket for connection of shakers, magnetic mixers etc. in the test room. Switching-on times can be freely programmed by means of the CONTROL2015 touch.

Electromagnetic door release by means of the CONTROL2015 touch. Door unlocking only after successful authorization with entry in the logbook (name, date, time).

Collecting pan for dew water or condensate. It can be easily withdrawn to the front.

Convenient application: A self-controlling heating rod ensures automatic evaporation of the condensate. Thus, periodical emptying is not required.

Export execution for power supply 110 V/60 Hz.

Communication and Software

Additional measuring sensor PT1000 for temperature control and recording of specimen.

Analogue output test room temperature for external recorder Signal 0-10 V, 0-20 mA, 4-20 mA

Analogue output test room humidity for external recorder Signal 0-10 V, 0-20 mA, 4-20 mA

- Monitoring of up to 32 appliances   - Compatible with Control 2000 and Control2015 touch   - Data logging and graph representation   - Logging of door openings with time stamp   - Logging of alarms with time stamp   - Automated daily print is possible   - Weekly and monthly print   - Archiving per day and control circuit   - Automated backup on server drive  

- Monitoring of appliances with Control2015 touch - Data safety in conformity with the guidelines 21CFR Part 11 - All events are recorded in a digital logbook, inseparably connected with the recorded data. - Signature in connection with the user management of the appliances - Automated prints  - Automated backup on server drive

Calibration and Qualification

Calibration on site with 9 spatially distributed sensors with a temperature value.

Calibration on site with 9 spatially distributed sensors with a temperature/humidity value.

Calibration on site with 9 spatially distributed sensors with a temperature value.

Calibration on site with 9 spatially distributed sensors with a temperature/humidity value.

We are always ready to support the validation of your appliances. If desired, the validation can be executed by our company. The validation includes the necessary measurements, as well as any documents, such as DQ, IQ, OQ and PQ, manuals, wiring diagrams, plans, appliance logbook, manufacturer certificates for the sensors and for the most important components. If required, we are also at your disposal for the annual recalibration.

Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.

Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature/humidity value on site.

Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.

Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature/humidity value on site.

    Title*

    Academic Title

    First Name*

    Surname*

    Company / Institute*

    Department

    Street*

    House Number*

    ZIP*

    City*

    Country*

    E-Mail-Adress*

    Phone*

    Newsletter

    Yes, I want to receive RUMED's free newsletter. I can unsubscribe easily at any time.

    Request catalogue

    Subject

    Info

    Please enter the unit type (1) and the serial number (2) into the enquiry form.

    BUnit type and serial number of the Control 2000 are displayed after actuation of the key i.

    Your Message