Sie befinden sich hier: Startseite » Produkte » XWS-X820 Ex Heat Cabinet

XWS-X820 Ex Heat Cabinet

Product Information

  • Temperature Range 0 to +80 °C
  • Test Room 820 Litres
  • Use in Ex Area Zone 1 and 2
  • EC Type examination according to Directives 2014/34/EC
  • Digital Control
  • Optional dehumidification and humidification
TypeXWS-X820
Test Room
Volume820 l
Temperature Range0 to +80 °C
Deviation in Time±0,5 °C
Height1500 mm
Width610 mm
Depth935 mm
Number of shelves 4
Maximum load per shelf25 kg
Appliance
Height2105 mm
Width760 mm
Depth1475 mm
Electr. Connection400/230 V / 50 Hz
Net weight of the standard unit340 kg
Refrigerant
Type / GWPR134a / 1430
CO2-Equivalent1,416 t

Enquiry Questionnaire

Please choose the options, which are relevant for the product enquiry.

Temperature Options

test

Extension of the minimum temperature to -20 °C.

test

Augmentation of the speed of temperature change to 1 °C/min in the temperature range of 0 °C to +35 °C.

test

Augmentation of the speed of temperature change to 1 °C/min in the temperature range of -20°C to +80°C.

Humidity Options

The evaporation humidifier is the exclusive way of humidification of the ECO Appliance Line. The Premium-Line furthermore includes the high-precision controllable ultrasonic atomization.

Ion exchanger for direct connection to the drinking water pipe, if demineralized water supply is not available.

Canister for water supply at installation places without water connection.

Optional Accessories

Their maximum carrying capacity is up to 25 kg.

The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests. Their maximum carrying capacity is up to 50 kg.

Their maximum carrying capacity is up to 50 kg. The reinforced stainless-steel grid shelves are recommendable for building material testing or beer forced-ageing tests.

The triple glazed glass panel door always ensures an optimum view into the test room.

A 45 mm duct in the lateral panel allows insertion of measuring lines and hoses into the test room. Delivery including cover.

Gas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes.

Mobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake.

Collecting pan for dew water or condensate. It can be easily withdrawn to the front.

Export execution for power supply 110 V/60 Hz.

The option Program Control allows complex, several days' programs with cyclizations and loops.

The digital recorder of the X Line is working without any paper, and it can be equipped with a digital interface, just like the controller. Due to corresponding transmitters, recording and control can be executed in non-explosion proof areas.

Calibration and Qualification

Calibration on site with 9 spatially distributed sensors with a temperature value.

Calibration on site with 9 spatially distributed sensors with a temperature/humidity value.

Calibration on site with 9 spatially distributed sensors with a temperature value.

Calibration on site with 9 spatially distributed sensors with a temperature/humidity value.

We are always ready to support the validation of your appliances. If desired, the validation can be executed by our company. The validation includes the necessary measurements, as well as any documents, such as DQ, IQ, OQ and PQ, manuals, wiring diagrams, plans, appliance logbook, manufacturer certificates for the sensors and for the most important components. If required, we are also at your disposal for the annual recalibration.

Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.

Execution and documentation of the design qualification, qualification of installation and operation qualification including calibration on site with 9 spatially distributed sensors with a temperature/humidity value on site.

Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature value on site.

Execution and documentation of the performance qualification including calibration on site with 9 spatially distributed sensors with a temperature/humidity value on site.

    Title*

    Academic Title

    First Name*

    Surname*

    Company / Institute*

    Department

    Street*

    House Number*

    ZIP*

    City*

    Country*

    E-Mail-Adress*

    Phone*

    Newsletter

    Yes, I want to receive RUMED's free newsletter. I can unsubscribe easily at any time.

    Request catalogue

    Subject

    Info

    Please enter the unit type (1) and the serial number (2) into the enquiry form.

    BUnit type and serial number of the Control 2000 are displayed after actuation of the key i.

    Your Message